GATE Control Station for ANDROID


GATE Control Station v1.3.0
Release date: 12-11-2018
Added:
- full support for Titan V2 NGRS
- warning about dangerous trigger setting (too high sensitivity)
Improved:
- a way of highlighting sensors states
- GUI fixes
- various bug fixes


GATE Control Station v1.2.0
Release date: 01-08-2018
Added:
- Possibility to upgrade firmware edition directly from the app
- Secure PayPal payments
- Automatic firmware download and install
- Possibility to turn off switching pre-cocking mode via fire selector
- Mail
Improved:
- Dashboard
- Bug fixes
- 64 minor improvements
Changed:
- The name "pre-cocking smart" has been changed to "pre-cocking trigger". The functionality has not changed.


GATE Control Station v1.1.5
Added:
- Support for Android 8.1


GATE Control Station v1.1.4
Improved:
- Trigger sensitivity and fine calibration adjustment


GATE Control Station v1.1.3
Improved:
- Various bug fixes


GATE Control Station v1.1.2
Improved:
- Various bug fixes


GATE Control Station v1.1.1
Improved:
- Register & login
- Various bug fixes


GATE Control Station v1.1.0
Added:
- GCS account support: logging in, account card
- Support for TITAN V3
Improved:
- Various bug fixes


GATE Control Station v1.0.0
Initial release.

 

GATE Control Station for WINDOWS


GATE Control Station v2.6
Release date: 12-11-2018
Added:
- full support for Titan V2 NGRS
- warning about dangerous trigger setting (too high sensitivity)
Improved:
- a way of highlighting sensors states
- various bug fixes


GATE Control Station v2.5
Release date: 01-08-2018
Added:
- Automatic firmware download and install
- Possibility to turn off switching pre-cocking mode via fire selector
- Mail
Improved:
- Dashboard
- Bug fixes
- Lots and lots of minor improvements
Changed:
- The name "pre-cocking smart" has been changed to "pre-cocking trigger". The functionality has not changed.


GATE Control Station v2.4
Release date: 21-11-2017
Added:
- TITAN V3 support
Changed:
- SENSORS page has 2 cards for different TITAN versions: V2 and V3


GATE Control Station v2.3
Release date: 05-10-2017
Added:
- Active brake settings which allows to adjust motor braking power manually [available only with firmware 2.1 or newer]
Changed:
- Now regional lock is displayed only if active


GATE Control Station v2.2
Release date: 14-09-2017
Added:
- Firmware editions support
Improved:
- Changing gear ratio automatically reset cycle adaptation data. There is no need to restore factory settings after changing gear ratio.


GATE Control Station v2.1
Release date: 07-07-2017
Added:
- Possibility to install beta version of firmware
- Regional lock for SEMI ONLY (can be activated only by distributors)
- Gear Ratio: 19-TOOTH (available with next firmware version)
- Statistics' description
- Ranking
- Privacy Policy
- Profile menu


GATE Control Station v2.0
Release date: 31-03-2017
Improved:
The whole new GUI.


GATE Control Station v1.1
Release date: 21-02-2017
Added:
1. DTC errors colors:
Blue - information codes. Do not require any action
Yellow - the problems that can be solved by user
Red - the problems that require contact with GATE Support Team
2. Selector calibration procedure (Advanced -> Selector calibration).
3. Equalizer function settings.
4. Sounds when switching selector or trigger position.


GATE Control Station v1.0
Release date: 14-12-2016
Improved: 
1. Setting the sensitivity of the trigger after a Reset Factory Settings and Default Settings.
Added: 
1. Documentation (Help -> Manuals).
2. User Data for send report to GATE. To send report user must enter his email address and country.


GATE Control Station v0.9
Release date: 24-11-2016
- First public beta release

 

GATE Control Station for MAC


GATE Control Station v2.6
Release date: 12-11-2018
Added:
- full support for Titan V2 NGRS
- warning about dangerous trigger setting (too high sensitivity)
Improved:
- a way of highlighting sensors states
- various bug fixes


GATE Control Station v2.5
Release date: 01-08-2018
Added:
- Automatic firmware download and install
- Possibility to turn off switching pre-cocking mode via fire selector
- Mail
Improved:
- Dashboard
- Bug fixes
- Lots and lots of minor improvements
Changed:
- The name "pre-cocking smart" has been changed to "pre-cocking trigger". The functionality has not changed.


GATE Control Station v2.4
Release date: 21-11-2017
Added:
- TITAN V3 support
Changed:
- SENSORS page has 2 cards for different TITAN versions: V2 and V3


GATE Control Station v2.3
Release date: 05-10-2017
Added:
- Active brake settings which allows to adjust motor braking power manually [available only with firmware 2.1 or newer]
Changed:
- Now regional lock is displayed only if active.


GATE Control Station v2.2
Release date: 14-09-2017
Added:
- Firmware editions support
Improved:
- Changing gear ratio automatically reset cycle adaptation data. There is no need to restore factory settings after changing gear ratio.


GATE Control Station v2.1
Release date: 07-07-2017
Added:
- Possibility to install beta version of firmware
- Regional lock for SEMI ONLY (can be activated only by distributors)
- Gear Ratio: 19-TOOTH (available with next firmware version)
- Statistics' description
- Ranking
- Privacy Policy
- Profile menu


GATE Control Station v2.0
Release date: 31-03-2017
Improved:
The whole new GUI.


GATE Control Station v1.1
Release date: 21-02-2017
Added:
1. DTC errors colors:
Blue - information codes. Do not require any action
Yellow - the problems that can be solved by user
Red - the problems that require contact with GATE Support Team
2. Selector calibration procedure (Advanced -> Selector calibration).
3. Equalizer function settings.
4. Sounds when switching selector or trigger position.


GATE Control Station v1.0
Release date: 21-12-2016
- First public beta release

 

TITAN firmware


If you cannot see your device on the list or it is accompanied by exclamation mark it means that you must install the device’s driver manually. You can download the driver here: http://www.ftdichip.com/Drivers/VCP.htm


TITAN V2 firmware


TITAN V2 – ver. 2.2b05
Release date: 01-08-2018
Added:
- Possibility to turn off switching pre-cocking mode via fire selector


TITAN V2 – ver. 2.1
Release date: 08-11-2017
Added:
- Possibility to adjust motor braking power


TITAN V2 – ver. 2.0
Release date: 27-07-2017
Added:
- Statistics
- Rankings
- Compatiblility with 19-tooth sector gear
- Regional Lock
Improved:
1. Pre-cocking setup via fire selector. Now you do not need to fire the shot to switch pre-cocking mode. You can do it in two ways:
a) Switch fire selector to SAFE and pull the trigger
b) Switch fire selector to SEMI, fire the shot and keep the trigger pulled
While the trigger is pulled you are able to select pre-cocking mode:
SAFE = Pre-cocking OFF,
SEMI = Pre-cocking SMART,
AUTO= Pre-cocking AUTO
2. Motor emergency shutdown with fire selector. It is possible only when switching AUTO to SAFE. Switching fire selector between SEMI <–> AUTO or SEMI <–> SAFE during the shot does not induce any break of cycle or vibration.
3. Low battery warnings. User is warned five times before battery is discharged. Each warning is communicated via three vibrations: HIGH ->MID ->HIGH.
4. Changed type of notifying user about discharged battery (UVP1). Now these are three vibrations: HIGH ->MID ->LOW.


TITAN V2 – ver. 1.9
Release date: 21-02-2017
Improved:
1. UVP2 protection – a new power supply algorithm. You can shoot more BB's with the same battery. Now TITAN works much more efficiently with weak, low capacity batteries (also NiMH and NiCd).
2. Trigger detection algorithm
3. Pre-cocking SMART
4. ROF Stabilization
5. Self-test for voltage higher than 16.5V
New functions:
1. Trigger equalizer configuration (OFF, EQ1, EQ2).
OFF - to fire a next shot, you need to release the trigger until it reaches the selected trigger sensitivity level 
EQ1 - to fire a next shot, it is enough to release the trigger so as it changes the state of two trigger sensors
EQ2 - to fire a next shot, it is enough to release the trigger so as it changes the state of one trigger sensor
EQ1 or EQ2 are especially useful when the trigger sensitivity level is very high. Then you don't need to fully release the trigger while quickly firing on SEMI.
2. Fire selector sensors calibration (via GCS). Your selector will work even more precisely.
3. Option to turn off the motor via switching fire selector when CYCLE DETECTION is OFF.


TITAN V2 – ver. 1.8
Release date: 06-12-2016
Improved:
1. Trigger detection. Added compatibility with speed triggers and triggers with hole. Fixed problem with double shooting while trigger release.
2. Diagnostic Trouble Codes detection.

 

TITAN V3 firmware


TITAN V3 – ver. 0.5b02
Release date: 04-10-2018
The algorithm of the gear sensor has been improved.


TITAN V3 – ver. 0.5b01
Release date: 01-08-2018
Added:
- Possibility to turn off switching pre-cocking mode via fire selector


TITAN V3 – ver. 0.4
Release date: 01-08-2018
Stable release.